All hours past noon must be entered in the range 13-23. When you press ENTER to select a time
change, the M3000 resets seconds to zero.
Non Portable Mode (Nonport. Mode)
Pressing the SHIFT key from the "Portable Mode Selection Function" display places the
M3000 in one of three non portable modes. The availability of the these modes is dependent on
the non portable mode selected with this option. The non portable modes designate how the
M3000 sends data to the personal computer, or host computer. Only bar code data is sent. Data is
not sent from the M3000 keypad. For information on Data File Transmissions, refer to
Transmission Setup.
The automatic shut-off feature is disabled during all non portable operations.
Keyboard Wedge
The default non portable mode is Keyboard Wedge. When the Keyboard Wedge Y-cable is
connected, the M3000 switches to the Keyboard Wedge mode automatically, regardless of the Non
Portable mode setting. During Keyboard Wedge operation the M3000 receives all its power from
the keyboard port, and does not use its internal battery. Keyboard Wedge setup options must
match your current computer configuration.
When connected as a Keyboard Wedge, the M3000 always turns ON and OFF with the computer.
Serial Wedge
When used as a Serial Wedge, the M3000 sends bar code data to the host computer just as if the
data were typed from the terminal keyboard. Serial Wedge operation is enabled by the following
conditions:
Connection of the Serial Y-cable
Serial Wedge selected as the Non Portable mode
M3000 Serial Port settings match comparable settings on the host computer.
The SHIFT key is pressed from the "Portable Mode Select Function" display
Pressing SHIFT again, returns you to the portable mode.
NOTE: During Serial Wedge and RS-232 Serial operation, the M3000 operates on either battery
power or the external power supply. We recommend you use the external power supply
that was shipped with your M3000, if you intend to operate in the serial modes for any
extended period of time. Extended use in these non portable modes without the external
power supply installed, reduces battery life.
RS232 Serial
When used in the RS232 Serial mode, the M3000 sends bar code data to any RS-232 Serial Port.
When using SOFTCOM keyboard emulation software with any DOS based computer, the RS-232
data appears just as if it were typed from the computer keyboard. RS232 Serial operation is
enabled by the following conditions:
Connection of the Serial cable
RS-232 Serial selected as the Non Portable mode
M3000 Serial Port settings match comparable settings on the receiving computer
Proper installation of SOFTCOM keyboard emulation software (if needed).